ZXMW NR8250 Alarm and Notification Handling Reference
l
The board cannot operate properly, and the services carried by the board are
interrupted.
Possible Causes
1.
The running software is damaged.
2.
The running software is lost.
3.
The running software does not exist in the software package (no corresponding SWID).
Handling Procedure
In the software version management window, select
Maintenance > Version > IDU
,
re-download the correct software version package.
2.3.9 6209 Main control software version synchronization failure
Alarm Property
l
Alarm Code: 6209
l
Alarm Information: If the active main control board fails to synchroize its software
version with that of the standby main control board, the alarm is reported.
l
Alarm Level: Major
l
Alarm Type: Handling Alarm
Sub-code Description
l
Sub-code 0: CPU software
l
Sub-code 1: FPGA software
Effect on the System
The active/standby changeover cannot be implemented.
Possible Causes
1.
The software version of the main control board is incorrect.
2.
The hard disk space of the standby main control board is insufficient.
3.
The standby main control board is faulty.
Handling Procedure
1.
Delete the redundant files on the standby main control board. If the alarm persists, go
to step 2.
2.
Replace the board.