ZXMW NR8250 Alarm and Notification Handling Reference
Handling Procedure
1.
For sub-code 1, correctly configure the XPIC function on the client.
2.
For sub-code 2, ensure that the pair of RMUCs each of which is configured with the
XPIC function use the same bandwidth.
3.
For sub-code 3, ensure that the two RMUCs with the XPIC function enables use a
bandwidth higher than 28 M.
4.
For sub-codes 4 and 5, replace the board hardware based on the alarm information.
5.
For sub-code 6, check the XPIC hardware connection and ensure that the XPD value
is greater than 25 dB.
6.
For sub-code 7, modify the ODU frequency and ensure that the pair of RMUCs each
of which is configured with the XPIC function use the same ODU frequency.
Ensure that the two RMUC boards of an XPIC group use the same bandwidth.
2.1.17 134239937 ODU power supply abnormal
Alarm Property
l
Alarm Code: 134239937
l
Alarm Information: The alarm is reported when the -48V power supply of ODU is
abnormal or lost.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
If the power supply of ODU is abnormal, the power supply of RMU also becomes abnormal,
and the problems of error codes or service interruption will occur.
Possible Causes
The hardware of power supply is faulty or the power supply is abnormal.
Handling Procedure
1.
Check whether the power supply is normal.
l
If yes, go to step 2.
l
If no, remove the power fault.
2.
Replace the ODU power module.
2-14
SJ-20111008094748-008|2012–05–30 (R1.1)