6-5
Chapter
6
SAFETY
I/O INTERF
ACE
■
Emergency stop input signal connection (2)
Connection when using the RPB-E (provided with an enable switch) with an external
emergency stop circuit
Selector
13
14
RPB connector
SAFETY
connector
13 E-STOPIN1
11 E-STOP24V
12 E-STOPRDY
RPB-E
External emergency
stop circuit
DC24V
GND24V
Main power supply
control circuit
Control signal
detection circuit
L
N
Motor drive
circuit
Internal control
circuit
15
16
17
18
19
20
21
22
14 E-STOPIN2
10
1 DI.COM
3 SERVICE
External service mode
stop circuit
Enable switch
8 KEY1
9 KEY2
1. SAFETY I/O interface overview