![Yamaha CEmarking RCX221 User Manual Download Page 244](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670244.webp)
4-176
Chapter
4
OPERA
TION
12. "SYSTEM" mode
2. Data display length/DATLEN
This parameter sets the number of digits to display such as for point data. This is
automatically set to "6char" (6 digits) when the parameters are initialized.
[Procedure]
1) Select "2. Data display length" in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting the "Data display length"
SYSTEM
>PARAM>OTHERS
V9.08
1.Display language(JPN/ENG) ENGLISH
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Incremental Mode INVALID
6char
8char
3) Press
(6char) or
(8char).
4) Press
to quit the edit mode.