12. "SYSTEM" mode
7. TRUE condition / EXPCFG
This parameter selects the operation when the conditional expression, which is used
for the STOPON option in an IF (including ELSEIF), WHILE to WEND, WAIT, MOVE,
or DRIVE statement, is a numeric expression.
This parameter is set to "-1" when the parameters are initialized.
n
NOTE
This parameter is supported by controllers of Ver. 9.08 onwards.
[Procedure]
1) Select "7. TRUE condition" in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting "TRUE condition"
SYSTEM
>PARAM>OTHERS
V9.08
−1
not 0
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Incremental Mode INVALID
6.DI noise filter VALID
7.TRUE condition -1
3) Press
(-1) or
(not 0) to change the setting.
Setting
Meaning
-1 (default setting)
When conditional expression is a numeric expression, the
result is "TRUE" if the expression value is -1, and is "FALSE"
if 0. If the value is other than -1 and 0, an error "6.35:
EXPRESSION ERROR" occurs.
not 0
When conditional expression is a numeric expression, the
result is "TRUE" if the expression value is other than 0, and is
"FALSE" if 0.
4) Press
to quit the edit mode.
Summary of Contents for CEmarking RCX221
Page 2: ......
Page 6: ...4 MEMO...
Page 16: ......
Page 30: ......
Page 38: ......
Page 62: ...3 24 MEMO...
Page 68: ......
Page 342: ......
Page 366: ...5 24 MEMO...
Page 368: ......
Page 384: ......
Page 396: ......
Page 404: ...8 8 MEMO...
Page 406: ......
Page 467: ...MEMO...