![Yamaha CEmarking RCX221 User Manual Download Page 294](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670294.webp)
4-226
Chapter
4
OPERA
TION
12. "SYSTEM" mode
2. Direct connection from DI n ( ) to SO n ( )
Parallel port input can be directly connected to serial port output. The relation
between serial and parallel ports that can be set is as follows.
n
NOTE
Output results might be incorrect if the SIO specifi ed port is the same as the
port used by the program.
Input devices such as sensors
DI port
→
SO port
DI2()
SO2()
DI3()
SO3()
DI4()
SO4()
DI5()
SO5()
[Procedure]
1) Select from 5 to 8 in "SYSTEM>OPTION>SIO" mode.
2) Press
(EDIT).
■
Editing the SIO settings (2)
SYSTEM
>OPTION>SIO
V9.00
4.Direct SI5()->DO5()
NO
5.Direct SO2()<-DI2()
NO
6.Direct SO3()<-DI3()
NO
7.Direct SO4()<-DI4()
NO
8.Direct SO5()<-DI5()
NO
SET
NO
3) Press
(SET) to set the direct connection or press
(NO) not to set it.
4) Press
to quit the setting. To continue selecting other items, use the cursor (
↑
/
↓
)
keys.