12. "SYSTEM" mode
15. Origin direction /ORGDIR
This parameter specifies the direction for return-to-origin or absolute search. When
initialized, this is automatically set according to the current robot model.
"---" ...... Return-to-origin or absolute search direction is in the manual movement
minus (-) direction.
"+++" .... Return-to-origin or absolute search direction is in the manual movement
plus (+) direction.
c
CAUTION
• YAMAHA can accept no liability from problems arising due to changing
the return-to-origin direction without consulting YAMAHA beforehand.
• Return-to-origin will be incomplete if this parameter is changed.
[Procedure]
1) Select "15. Origin direction" in "SYSTEM>PARAM>AXIS" mode.
2) Press
(EDIT).
3) Select the parameter with the cursor (
↑
/
↓
) keys.
■
Setting the "Origin direction"
SYSTEM
>PARAM>AXIS V9.00
15.Origin direction
M1=–––
M2=–––
–––
+++
4) Press
(---) or
(+++).
5) Repeat the above steps 3) and 4) if necessary.
6) Press
to quit the edit mode.