![Yamaha CEmarking RCX221 User Manual Download Page 257](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670257.webp)
4-189
Chapter
4
OPERA
TION
12. "SYSTEM" mode
12.1.4.1 Option DIO setting
Make the DIO option board setting as explained below.
Parameter
Meaning
1
Board condition
Sets whether to issue an error "12.31: DI DC24V
disconnected" when the 24V power supply is not
connected.
When set to "INVALID", no error will be issued even if
the DC 24V power supply is disconnected.
This parameter cannot be set to "INVALID" while the
24V power supply is connected to the DIO board.
This parameter automatically changes to "VALID" when
the 24V power supply is connected.
2
IO cmd (DI05)
(when ID=1)
Sets whether to use the dedicated input DI05 (IO
command run) function.
This is available only for the DIO board with ID=1.
[Procedure]
1) In "SYSTEM>PARAM>OP. BRD" mode, select "DIO_N(n)" or "DIO_P(n)" and press
(SELECT).
2) Press
(EDIT).
■
Option DIO setting
SYSTEM
>PARAM>OP.BRD
V9.00
1.Board condition
2.IO cmd(DI05)
VALID
INVALID
INVALID
VALID
3) Press
(INVALID) or
(VALID) to change the setting.
4) Select the parameter to be edited using the cursor (
↑
/
↓
) keys.
5) Press
to end the setting.
Summary of Contents for CEmarking RCX221
Page 2: ......
Page 6: ...4 MEMO...
Page 16: ......
Page 30: ......
Page 38: ......
Page 62: ...3 24 MEMO...
Page 68: ......
Page 342: ......
Page 366: ...5 24 MEMO...
Page 368: ......
Page 384: ......
Page 396: ......
Page 404: ...8 8 MEMO...
Page 406: ......
Page 467: ...MEMO...