Disable Exit
Time
Select if no exit timer is required and setting is activated by ‘Exit term’ zone or ‘Entry exit’ zone with
‘Final exit’ attribute. See
Fob Unset
Entry
FOB will only unset when entry timer is running. Default is enabled.
Access
Denied on
Alarm
Access is temporarily denied to the area for the amount of time specified in the Lockout Post Alarm
timer.
Prevent
Setting
If enabled, setting prevented from keypad
Prevent
Unsetting
If enabled, unsetting prevented from the keypad.
Setting
Authorisation
Used for configuring Blocking Lock operation. Options are:
l
Disabled
l
Set
l
Unset
l
Set and Unset
If the Disabled option is selected (default) then the system will set and unset normally with no
change of operation.
If the Set option is selected, a “Setting Authorisation” signal is required to set this area which can
be received from keypads or a zone input (see Authorised Setting of the Blocking Lock) The user
cannot set the system from the keypad. Any area that requires setting authorisation will appear as
locked on the comfort keypad and will not appear on the standard keypad when setting.
If the Unset option is selected, the user cannot unset the area from keypads but can use the
keypad to generate the setting authorization signal.
For the set and unset options, the user will be unable to change the state of the area at any stage
from the keypad.
A timer for setting authorisation can be configured. See
Partset Options
Configure the operation of particular zones for both Partset A and Partset B modes as detailed below:
Partset
Enable
Enable PartSet for A and B operation as required.
Partset
Timed
Tick the relevant checkbox (Partset A or B) to apply the exit timer to the Partset A or B mode.
Partset
Access
Tick the relevant checkbox to change access zones into entry/exit type zones for either Partset A
or B operation. This feature is useful for a domestic installation where a Passive Infrared (PIR)
sensor is located in the hallway. If the user partsets the system at night and returns downstairs
during the night, he/she may unintentionally activate the PIR sensor in the hallway and trigger the
alarm. By setting the partset access option, the buzzer will sound for the entry time period when the
PIR sensor is activated thereby warning the user that the alarm will activate if no action is taken.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
272
A6V10276959-d
11.2018