2. Complete the ATP fields described in the table below.
Panel Identification
ATP Sequence
No.
This field displays the sequence number of the ATP in the ATS
configuration. Number 1 is primary, numbers 2–10 are backup.
ATP Unique ID
When you save an ATP, the system assigns a unique ID to an ATP.
This is the unique ID of the ATP so it can be recognised by the RCT.
ATP Name
Enter a name for the ATP.
SPT Account
Code
Enter a number to uniquely identify the panel to the RCT.
RCT Identification
RCT ID
Enter the number that uniquely identifies the RCT (for example, SPC
Com XT) to the panel. This must match the number entered in the field
Server RCT ID
in the SPC Com XT Server Configuration Manager tool.
RCT URL or IP
Address
Enter the URL or IP address of the RCT (for example, SPC Com XT).
RCT TCP Port
Enter the TCP Port that the RCT (for example, SPC Com XT) listens
on. The default is 52000. This must match the value in the field
Server
FlexC Port
in the Server Configuration Manager tool. See the
SPC
Com XT Installation & Configuration Manual
.
ATP Interface
Communications
Interface
From the dropdown list, select the interface this ATP uses for
communication.
l
Ethernet
l
GPRS: Modem 1
l
GPRS: Modem 2
l
Dial Up Internet: Modem 1
l
Dial Up Internet: Modem 2
ATP Category
Select the category to apply to this ATP. For information on ATP
Categories, see
Advanced
Advanced ATP
Settings
It is not recommended to change advanced settings. Changes must
only be made by expert users.
3. If required, click
Advanced ATP Settings
, for example, if you are using auto encryption you can
optionally enter a password in the
Encryption Password
field. See
4. Click
Save
.