Restriction
System
Option
Description
Hide bypass
If enabled, the bypass messages will no longer be displayed on keypad.
Battery
capacity
Total batteries capacity in AH, for panel only (3–100Ah). You must enter this
value and
Max current
value to view the remaining battery time on the keypad
in the event of mains failure. This is indicated under the STATUS > BATTERY
> BATT TIME menu.
Max current
The total current draw from batteries when mains fail occurs (30–20000mA).
You must enter this value and the
Battery capacity
value to view the remaining
battery time on the keypad in the event of mains failure. This is indicated under
the STATUS > BATTERY > BATT TIME menu.
Partset
Partset A
Rename
Enter a new name for your PARTSET A mode (for example, Night Mode).
Partset B
Rename
Enter a new name for your PARTSET B mode (for example, Floor 1 only).
Alarm
Bell on First
Enable to activate relevant bells/sirens on an unconfirmed alarm. When this
option is disabled, the relevant bells/sirens will only activate on a confirmed
alarm or if the detector that caused the unconfirmed alarm is reactivated.
Bell Retrigger
Enable to resound bells/sirens if a second zone activation is detected (after the
bell time has elapsed). If not checked then the external bells will only trigger
once.
Web Only
Alert Forbid Set
If enabled, a user cannot set an area if there is an area or system alert present
on the system.
Note:
This option is only available when the
Standards > Region
selected is
Switzerland or
Security Grade
selected is ‘Unrestricted’.
Restore on
Unset
Enable for alerts to auto clear after 30 seconds in Unset mode.
Note:
To comply with PD6662, you must disable this option.
Antimask Set
Select the type of event reported resulting from antimask detection when panel
is Set. Options are Disabled, Tamper, Trouble or Alarm.
The option can only be configured when the panel is in ‘Unrestricted’ mode. In
Grade 2 or 3 mode, the type of event reported is in accordance with the
standards for the selected region:
l
Ireland - Alarm
l
All other regions - Alarm