Output Type
Description
Modem 2 Line
Fault
This output activates when there is a line fault on the secondary modem.
Modem 2
Failure
This output activates when the secondary modem fails.
Battery Low
This output activates when the battery is low.
Entry Status
This output activates if an ‘All Okay’ entry procedure is implemented and there is no alarm generated,
that is, the ‘All Okay’ button is pressed within the configured time after the user code is entered.
Warning
Status
This output activates if an ‘All Okay’ entry procedure is implemented and a silent alarm generated,
that is, the ‘All Okay’ button is not pressed within the configured time after the user code is entered.
Ready to Set
This output activates when an area is ready to set.
Setting ACK
This output signals the setting status. The output toggles for 3 seconds to signal that the setting has
failed. The output remains on for 3 seconds if setting is successful.
Fullset Done
This output activates for 3 seconds to signal that the system has been fullest.
Blockschloss
1
Used for normal Blockschloss devices.
When all zones in an area are closed, and there are no pending faults, the ‘Blockschloss 1‘ output is
activated. If the lock on the Blockschloss is closed, a ‘Keyarm‘ input is activated, the relevant area is
set and the ‘Setting Ack‘ output is activated for 3 seconds to signal that the setting was successful.
‘Blockschloss 1‘ is not deactivated.
If the Blockschloss is unlocked, the Blockschloss device deactivates the Keyarm input to the unset
state (closed) and the area is unset. ‘Blockschloss 1‘ is then deactivated.
Blockschloss
2
Used for Blockschloss device type - Bosch Blockschloss, Sigmalock Plus, E4.03.
When all zones in an area are closed, and there are no pending faults, the ‘Blockschloss 2‘ output is
activated. If the lock on the Blockschloss is closed, a ‘Keyarm‘ input is activated, the relevant area is
set and the ‘Setting Ack‘ output is activated for 3 seconds to signal that the setting was successful.
‘Blockschloss 2‘ is then deactivated.
If the Blockschloss is unlocked, the Keyarm zone is switched to unset (closed) and the area is unset.
‘Blockschloss 2‘ is activated (if area is ready to set).
Lock Element
Activates if the Lock Element is in the ‘locked‘ position.
Unlock
Element
Activates if the Lock Element is in the ‘unlocked‘ position.
Code Tamper
Activates if there is a code tamper in the area. Clears when state is reset.
Trouble
Activates if any zone is in trouble state.
Ethernet Link
Activates if there is a fault on the Ethernet link.
Network Fault Activates if there is an EDP communications fault.
Glass Reset
Used to switch on the power for the glassbreak interface module and to remove power in order to
reset the device. The output is reset if a user enters their code, the zone is not in the closed state,
and the bells deactivated.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the keypad