Name
Description
Area
(Web only)
The area the zone and the card reader are assigned to. (If the card reader is used for setting and
unsetting, this area will be set/unset).
Door
Position
(Web)
DPS End
Of Line
(keypads)
The resistor used with the door position sensor. Choose the used resistor value/combination.
DPS
Normal
Open
Select if the door release switch is to be a normally open or normally closed input.
Door
Release
(Web)
DRS END
OF LINE
(Keypads)
The resistor used with the door release switch. Choose the used resistor value/combination.
DRS
Normal
Open
Select if the door release switch is a normally open input or not.
No DRS
(Web only)
Select to ignore DRS.
If a DC2 is used on the door, this option MUST be selected. If not selected, the door will open.
Reader
Location
(Entry/Exit)
(Web only)
Select the location of the entry and exit readers.
Reader
formats
(Web)
READER
INFO
(Keypads)
Displays format of last card used with each configured reader.
Each free zone number can be assigned to the zones but the assignment is not fixed. If the number ‘9’
is assigned to a zone, the zone and an input expander with the address ‘1’ is connected to the X-Bus
(which is using the zone numbers 9–16). The assigned zone from the two door controller will be
moved to the next free zone number. Configuration will be adapted accordingly.
Door attributes
If no attribute is activated, a valid card can be used.