
l
DO NOT select the attribute
Setting State
in the
Keypad
configuration settings for
Visual
indications
.
Hardware Requirements
l
The back tamper kit (SPCY130) must be installed for panels and power supplies for compliance with
EN50131 Grade 3.
l
EN50131 Grade 3 compliant components must be installed for EN50131 Grade 3 compliant
systems.
l
Either EN50131Grade 2 or 3 compliant components must be installed for EN50131 Grade 2
compliant systems.
l
It is not possible to enrol a wireless device with a signal strength lower than 3.
l
The recommended ratio of wireless receivers to transmistters is no more than 20 transmitters for
every one receiver.
l
Glassbreak must be used with an EN-compliant glassbreak interface.
l
To comply with EN50131-3:2009, do not set or unset the system using the SPCE120 (Indicator
Expander) or the SPCE110 (Keyswitch Expander).
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Directives and standards
© Vanderbilt 2018
21
A6V10276959-d
11.2018