Name
Description
Reader
Location
(Entry/Exit)
(Web only)
Select the location of the entry and exit readers.
Reader
formats
(Web)
READER
INFO
(Keypads)
Displays format of last card used with each configured reader.
Each free zone number can be assigned to the zones but the assignment is not fixed. If the
number ‘9’ is assigned to a zone, the zone and an input expander with the address ‘1’ is connected
to the X-Bus (which is using the zone numbers 9–16). The assigned zone from the two door
controller will be moved to the next free zone number. Configuration will be adapted accordingly.
Door Groups
The different doors can be assigned to door groups. This is needed if one of the following functionalities
is activated:
l
Custodian
l
Soft Passback
l
Prevent Passback
l
Interlock
Door attributes
If no attribute is activated, a valid card can be used.
Attribute
Description
Void
The card is temporarily blocked.
Door Group
Used when multiple doors are assigned to the same area and/or anti-passback, custodian, or
interlock functionality is required.
Card and
PIN
Card and PIN are required to gain entry.
PIN Only
PIN is required. No card will be accepted.
PIN Code
or Card
PIN or card are required to gain entry
PIN to Exit
PIN is required on exit reader. Door with entry and exit reader is required.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the keypad
© Vanderbilt 2018
150
A6V10276959-d