Dial Up Internet Configuration
Dial Up
Internet
Enable
Select this option to enable the modem to gain internet access through a dial-up connection
Phone
Number
Enter the phone number for the dial-up connection.
Username
Enter the dial-up connection Username.
Password
Enter the dial-up connection Password.
Click the
Test SMS
button to send a short text message for the purposes of testing the system.
The SMS test is provided only for the purpose of ensuring the SMS feature is operating correctly. A
short text message using alphabetic characters (A-Z) should be used to test this feature.
PSTN modem
1. Select
Communications > Communications > Modems
.
2. Click
Configure
.
3. Configure the fields as described in the table below.
PSTN Modem settings
Country
Select the country that the SPC is installed in.
Incoming
Calls
The modem can be programmed to answer calls based on the following conditions:
l
Don’t answer incoming calls
Modem never answers calls.
l
Answer after ‘x’ rings
Select the number of rings (1 to 8) after which the modem answers the
incoming call.
l
Answer when after one ring phone is hung up, then immediately dialled again
If the
calling party calls the modem, hangs up after 1 ring burst only, and then immediately re-calls the
modem. The SPC system knows to automatically answer the call in this condition.
l
Only answer when engineer access is granted
The modem only answers the call while
engineer access is granted to the system.
Prefix
Enter the number required to access a line (for example, if connected to a PBX).
Line
Monitoring
Enable this feature to monitor the voltage of the line connected to the modem.
Note:
EN 50131-9 Confirmation configuration – In order for EN50131-9 Confirmation to operate
correctly, line monitoring must be enabled. (See
Monitoring
Timer
Select the period (in seconds) for which the line voltage must be seen as being incorrect before the
line is deemed by the SPC to be faulty.
Modem
Fault Time
Time delay for a system alert (0–9999 seconds). Default 60 seconds.