Zone Type
Processing
Category
Description
LOCK ELEMENT
Intruder
If using a Lock Element (bolt) with a Blockschloss, this zone type signals
the position of the lock element to the panel (locked or unlocked). This bolt
locks the door in the set state. This signal is checked during setting process.
If the ‘locked‘ information is not received, the setting will fail.
GLASSBREAK
Intruder
Zone is connected to an RI S 10 D-RS-LED glassbreak interface in
combination with GB2001 glassbreak detectors.
l
This zone type is available on controllers and expanders.
It is not available as wireless or as a door zone type if the DC2 is
configured as a door.
l
The zone type reports in the same way as an alarm zone over SIA and
contact ID.
l
The rights to restore/inhibit/isolate glassbreak are the same as the alarm
zone type
l
Power up condition — As the power is supplied by the panel any state
changes within the first 10 seconds are ignored in order to allow the
device to settle.
l
Reset condition — Signals are ignored from the glassbreak interface for
3 seconds after the device has been reset.
l
Exiting engineer mode — The glassbreak output may be toggled when
exiting engineer mode, in which case the signals from this sensor will be
temporarily ignored for 3 seconds.
WATER
This zone type follows the same behaviours as a Technical zone type.
HEAT
This zone type follows the same behaviours as a Technical zone type.
FRIDGE/FREEZER
This zone type follows the same behaviours as a Technical zone type.
GAS
This zone type follows the same behaviours as a Technical zone type.
SPRINKLER
This zone type follows the same behaviours as a Technical zone type.
CO
This zone type follows the same behaviours as a Technical zone type.
ENTRY/EXIT 2
This zone type follows the same behaviours as an Entry/Exit zone type with
a separate Entry timer. This is so that there can be two entry timers to a
building from different points.
*
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Appendix
© Vanderbilt 2018
383
A6V10276959-d