Output Type
Description
User Duress
This output turns on if a user duress state has been activated (PIN code + 1 has been entered on
the keypad).
PIR Masked
This output turns on if there are any masked PIR zones on the system. It generates a fault output
on the keypad led.
This output is latched so it will remain active until restored by a level 2 user.
PIR Masking is logged by default. The number of log entries do not exceed 8 between arming
periods.
Zone Omitted
This output turns on if there are any inhibited, isolated, or walk test zones on the system.
Fail to
Communicate
This output turns on if there is a failure to communicate to the central station.
Man Down
Test
This output turns on a ‘Man Down’ wireless device which is activated during a ‘Man Down’ test.
Unset
This output is activated if the system is in Unset mode.
Alarm Abort
This output activates if an alarm abort event occurs, that is, when a valid user code is entered via
the keypad after a confirmed or unconfirmed alarm. It is used, for example, with external dialers
(SIA, CID, FF).
Seismic Test
This output is used to activate a manual or automatic test on a seismic zone. Seismic sensors
have a small vibrator that will be attached to the same wall as the sensor and is wired to an output
on the panel or one of its expanders. During the test, the panel waits up to 30 seconds for the
seismic zone to open. If it does not open, the test fails. If it opens within 30 seconds the panel
then waits for the zone to close within 10 seconds. If that doesn’t happen, the test fails. The panel
then waits a further 2 seconds before reporting the test result. The result of the test, either manual
or automatic, is stored in the system event log.
Local Alarm
This output activates on a local intrusion alarm.
RF Output
This output activates when a Fob or WPA
1
button is pressed.
Modem 1 Line
Fault
This output activates when there is a line fault on the primary modem.
Modem 1
Failure
This output activates when the primary modem fails.
Modem 2 Line
Fault
This output activates when there is a line fault on the secondary modem.
Modem 2
Failure
This output activates when the secondary modem fails.
Battery Low
This output activates when the battery is low.
Entry Status
This output activates if an ‘All Okay’ entry procedure is implemented and there is no alarm
generated, that is, the ‘All Okay’ button is pressed within the configured time after the user code is
entered.
Warning
Status
This output activates if an ‘All Okay’ entry procedure is implemented and a silent alarm generated,
that is, the ‘All Okay’ button is not pressed within the configured time after the user code is
entered.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
234
A6V10276959-d
11.2018