3.5.2 Standards overview
Guidelines are provided for the implementation of PD 6662:2010 conformance for an SPC system to
the following relevant standards:
PD 6662:2010
BS 4737-3.1:1977
BS 8243:2010
BS 8473:2006+A1:2008
BS EN 50131-1:2006+A1:2009
BS EN 50136-1-1:1998+A2:2008
BS EN 50136-1-2:1998
BS EN 50136-1-3:1998
BS EN 50136-1-5:2008
BS EN 50136-2-1:1998 +A1:1998
BS EN 50136-2-2:1998
BS EN 50136-2-3:1998
BS EN 50131-3:2009
BS EN 50131-6:2008
DD 263:2010
DD CLC/TS 50131-7:2008
3.5.3 Methods for the completion of setting and unsetting
3.5.3.1 Methods of completion of setting (BS 8243:2010 - Clause 6.3)
Completion/Termination of the full setting procedure is achieved by any of the following methods:
a) Shunt lock fitted to the final exit door
A shunt lock must be installed by the installer as follows:
An EXIT TERMINATOR zone type must be configured for SPC.
See
b) Push button switch mounted outside the supervised premises
Connect the push button into an SPC zone input as follows:
An EXIT TERMINATOR zone type must be configured for SPC.
See
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual