Restriction
System
Option
Description
Alarm on
Reporting Fail
If a ‘Fail to Communicate‘ alert is raised, external bells will activate.
Retrigger
Duress
If enabled, duress alarm will retrigger.
Retrigger Panic
If enabled, panic alarm will retrigger.
Override
Reader Profile
If enabled, the LED behavior of readers will be controlled by the panel.
Silence Audio
Verification
If enabled, then the internal and external bells (system and area), the keypad
buzzers and annunciation messages on the Comfort Keypad will be silenced
during audio verification.
Watchdog
Output Mode
Enables output 6 on the SPC controller board to be used for monitoring
purposes. The following modes of operation of the watchdog output can be
selected:
l
Disable — Output 6 is available as a general purpose output.
l
Enabled — Output 6 is normally OFF but is turned ON when a watchdog
fault occurs.
l
Pulsed — Output 6 is PULSED at 100ms intervals.
l
Enabled Inverted — Output 6 is normally ON but is turned OFF when a
watchdog fault occurs.
The following options combine the Enabled option with hardware-fault reporting
in the event of a main microprocessor failure. If such a failure occurs, a SIA
event is sent to ARC1.
Note:
The ARC must be configured to use SIA and SIA Extended 1 or 2. CID
and FF are not supported by this reporting method.
l
E Reporting (10s) — The failure event is sent to ARC1 10
seconds after the fault is detected. This option must be used to comply
with VdS 2252.
l
EReporting (60s) — The failure event is sent to ARC1 60 seconds
after the fault is detected.
The SIA event reported is HF and Extended SIA reports
Hardware Fault
.
Note:
Hardware faults are not reported if the Engineer is logged in to the
system.
For more information on ARCs, see
Alarm Reporting Centres (ARCs)
SPCP355
Enable VdS power supply.
For VdS installations, this option is automatically selected.
Bell on Fail to
Set (FTS)
Enable to activate the internal bell if the system fails to set.
Strobe on Fail
to Set (FTS)
Enable to activate the strobe if the system fails to set.