Timer
Description
Default
Bell on Fullset
FULLSET BELL
Activates the external bell momentarily to indicate a full set condition. (0–10
seconds)
0sec.
Fail To Set
FAIL TO SET
Number of seconds to display fail to set message on keypads (0 until valid PIN is
entered). (0–999 seconds)
10sec.
Strobe on
Fullset
FULLSET
STROBE
Activates the strobe on the external bell momentarily to indicate a full set
condition. (0–10 seconds)
0sec.
Alarm
Double Knock
DKNOCK
DELAY
The maximum delay between activation’s of zones with the double attribute,
which will cause an alarm. (1–99 seconds)
10sec.
Soak
SOAK DAYS
The number of days a zone remains under soak test before it automatically returns
to normal operation. (1–99 days)
14 days
Seismic Test
Interval
SEISMIC
AUTOTEST
The average period between seismic sensor automatic tests. (12–240 hours)
Note:
To enable automatic testing, the
Automatic Sensor Test
attribute must be
enabled for a seismic zone.
168
hours
Seismic Test
Duration
SEISMIC TEST
DUR
Maximum time (in seconds) that a seismic sensor takes to trigger an alarm in
response to the 'Seismic Test' output. (3–120 seconds)
30sec.
Auto Restore
Delay
Time to delay auto restore after zone state returns to normal. (0–9999 seconds)
0sec.
Lockout Post
Alarm
LOCKOUT
POST ALARM
The duration of time after an alarm before the user can gain access. (1–120
minutes)
0min.
Access Time
The duration of time the system can be accessed by an alarm access user after
the Lockout Time has elapsed. (10–240 minutes)
External Bell
Strobe
STROBE TIME
Duration that the strobe output will be active when an alarm is activated. (1–999
minutes; 0 = indefinitely)
15min.
Alerts
Mains Delay
MAINS SIG
DELAY
The time after a mains fault has been detected before an alert is activated by the
system. (0–60 minutes)
0min.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
263
A6V10276959-d
11.2018