3. Enter a
Name
to identify the command profile.
4. Select an
Authentication Mode
(Command User or Panel User, Command User Only, or Any
Panel User) from the dropdown menu.
NOTICE: The default
Command User Name
provides an out of the box user that
quickly and easily enables control of the panel from SPC Com XT. It enables a
broad range of commands. For example, the default command user can set all
areas or control all zones. For tighter control, for example to only allow setting of
certain areas, you can set up a customised command profile with a defined set of
rights. You cannot delete the
Default Command Profile
, the
Default Portal
Command Profile
or a command profile that is assigned to an ATS.
5. Enter the name of the command profile user in the
Command User Name
field. This must match
the
Authentication User Name
field in SPC Com XT.
6. Enter the password of the command profile user in the
Command Password
field. This must
match the authentication
User PIN or Password
field in SPC Com XT.
7. Select the
Live Streaming Mode
(Disabled, Only after alarm event, Always available, System is
fullset) to determine the streaming privacy options.
Always Available
generates the highest
volume of data.
8. Under
Command Filter
, select the commands to enable. For a full list of commands, see
9. Select the commands to log.
10. Click
Save
.
11. Click
Back
to view the command profile in the
Command Profiles
table.
12. To change a command profile, click the
Edit
button (pencil icon) next to a command profile.
17.11.3 Reporting
This section covers:
l
Alarm Reporting Centres (ARCs)
l
l
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
323
A6V10276959-d
11.2018