Transmission time, max. values
M0 – M4
Reporting time
T3 as max.
Availability
See
ATS levels and attenuation specifications
Signalling security level
Tested to EN50136-1-1 and classified as ‘S0’.
3.6 Compliance with VdS approvals
This installation document encompasses the required product installation information for VdS
approvals.
Vanderbilt
SPC42xx/43xx/53xx/63xx : VdS Approval Nr. G 112104, G112124, and G112128. VdS EN Certificates
EN-ST000142, EN-ST000143, EN-ST000055, EN-ST000056, EN-ST000057, EN-ST000058, EN-
ST000061, EN-ST000062.
Siemens
SPC42xx/43xx/53xx/: VdS Approval Nr. G116035. VdS EN Certificates EN-ST000225, EN-
ST000226, EN-ST000227, EN-ST000228, EN-ST000229, EN-ST000230, EN-ST000231, EN-
ST000232.
This section describes the compliance of this system with VdS approvals.
Configuring software for VdS compliance
To set the system for VdS compliance, do the following:
1. Log on to the panel with the browser.
2. Click
Full Engineer
.
3. Click
Configuration > System > Standards
.
4. Select
Europe
in the
Continent
section of the page.
5. Select
Germany
in the
Region Compliance
section of the page.
6. Select the VDS grade required by your installation type.
Hardware Fault reporting — in
Configuration > System > System Options
, you must select the
E Reporting (10s)
option from the
Watchdog Output Mode
drop-down list.
Hardware faults are not reported if the Engineer is logged in to the system.
Hardware
VdS compliance requires the following:
l
A G5 housing with Front tamper implemented as a minimum requirement.
l
Keypads do not show status information if the system is armed.
l
The number of supported zones is as follows:
– 512 zones in ring configuration
– 128 zones per X-Bus in multi-drop (spur) configuration
l
The following end of line resistance combinations do not comply with VdS standards:
– 1k, 470 ohm
– 1k, 1k, 6k6 ohm
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual