Zone Type
Processing
Category
Description
DETECTOR
FAULT
Fault
Detector Fault zones are 24 hour zones that are applicable to a detector
device, for example, a PIR. The fault zone type triggers the Fault output.
When the system is armed, a fault output is triggered. Both the keypad LED
and the buzzer are activated when Unarmed.
LOCK
SUPERVISION
Intruder
Only available in Commercial mode.
Used to monitor a door lock. System can be programmed not to set unless
door is locked.
SEISMIC
Intruder
Only available if the panel is in Financial mode of operation. Vibration
sensors, also called seismic sensors, are used to detect intrusion attempts
by mechanical means, such as drilling or making holes through walls or
safes.
ALL OKAY
Intruder
This zone type enables a special entry procedure to be implemented using a
user code and ‘All Okay’ input. A silent alarm is generated if an All Okay
button is not pressed within a configurable time after a user code is entered.
(See
on page 270 for details of ‘All Okay’
configuration.)
All Okay uses two outputs, Entry Status (Green LED) and Warning Status
(Red LED), to indicate entry status using LEDs on the keypad.
UNUSED
Intruder
Allows a zone to be disabled without the need for each zone to have EOL
resistors fitted. Any activation on the zone will be ignored.
HOLDUP FAULT
Fault
Holdup Fault zones are 24 hour zones that are applicable to a holdup
signaling device, for example, a WPA*. The fault zone type triggers the Fault
output.
When the system is armed, a fault output is triggered. Both the keypad LED
and the buzzer are activated when Unarmed.
This zone type will report the SIA messages, HT (Holdup Trouble) and HJ
(Holdup Trouble Restore) and for CID, a sensor trouble event (380) is
produced.
WARNING FAULT
Fault
Warning Fault zones are 24 hour zones that are applicable to a warning
signaling device, for example, an internal or external bell. The fault zone type
triggers the Fault output.
When the system is armed, a fault output is triggered. Both the keypad LED
and the buzzer are activated when Unarmed.
This zone type will report the SIA messages, YA (Bell Fault) and YH (Bell
Restore) and for CID, a sensor trouble event (380) is produced.
Note:
On a grade 2 system, a cable fault will cause a fault and not an alarm.
SETTING
AUTHORISATION.
Intruder
Applicable to Blockschloss operation. This zone type is used to send a
setting authorisation signal to the panel that the Blockschloss is ready to
set. The Set option must be selected for the ‘Setting Authorisation‘ attribute
for the area