Attribute
Description
Void
The card is temporarily blocked.
Door Group
Used when multiple doors are assigned to the same area and/or anti passback, custodian, or
interlock functionality is required.
Card and
PIN
Card and PIN are required to gain entry.
PIN Only
PIN is required. No card will be accepted.
PIN Code
or Card
PIN or card are required to gain entry
PIN to Exit
PIN is required on exit reader. Door with entry and exit reader is required.
PIN to
Set/Unset
PIN is required to set and unset the linked area. The card has to be presented before the PIN is
entered.
Unset
outside
(Browser)
Panel/area will unset, when card is presented at entry reader.
Unset
inside
(Browser)
Panel/area will unset, when card is presented at exit reader.
Bypass
alarm
Access is granted if an area is set and the door is an alarm or an entry zone type.
Fullset
outside
(Browser)
Panel/area will fullest, when card is presented twice at entry reader.
Fullset
inside
Panel/area will fullest, when card is presented twice at exit reader.
Force
Fullset
If the user has rights, they can force set from entry reader.
Emergency
Door lock opens if a fire alarm is detected within the assigned area.
Emergency
any
Fire in any area will unlock the door.
Escort
The escort feature enforces privileged card holders to escort other card holders through specific
doors. If this feature is assigned to a door, a card with the “escort right” has to be presented first,
to allow other cardholders without this right to open the door. The time period in which cardholders
are able to present their cards after a card with escort right was presented, can be configured per
door.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
280
A6V10276959-d
11.2018