Reconfiguration completed
displays at the top of the page. E-Bus inputs and outputs display
in the list of
Configured Expanders
. If an input transponder has an associated PSU, the PSU type
displays in the
PSU
column. Keypads display in the list of
Configured Keypads
.
9. To complete the manual addressing steps to add the SAP 8, SAP 14, and SAP 20 PSU devices to
the list of
Configured Expanders
, see
Addressing Transponders for SAP 8, SAP 14, and SAP 20
10. If the X-BUS has addressing conflicts, the warning
Invalid or Duplicate ID for
Expander IDx
displays. Repeat the addressing steps above until there is no addressing conflict.
E-Bus
Device:
Dropdown
Menu
Description
ID Format
Addressing
Keypad
IDs to assign to Sintony
keypads
E-BUS ID (X-BUS
ID)
Hold keys 1 and 3 simultaneously until the
SPC E-Bus Gateway beeps continuously.
Input
IDs to assign to Sintony input
transponders
E-BUS ID (X-BUS
ID)
Hold the addressing button for 5 seconds
and release to hear a continuous beep.
Output
IDs to assign to Sintony output
transponders
E-BUS ID (X-BUS
ID)
Hold the addressing button for 5 seconds
and release to hear the SPC E-Bus Gateway
beeps continuously.
PSU
IDs to assign to Sintony PSU
devices SAP 8, SAP 14, SAP
20, and SAP 25
E-BUS ID (X-BUS
ID of associated
transponder)
Hold the addressing button until the SPC E-
Bus Gateway beeps continuously.
See also
23.21.1.1 Addressing Transponders for SAP 8, SAP 14, and SAP 20
After assigning a PSU ID to an SAP 8, SAP 14, or SAP 20, see
Configuring and Addressing E-Bus
on the previous page, you must assign an input transponder to the PSU. This simulates
communication to the SPC controller via an expander.
1. In the
Configured Expanders
list, select the
SPC E-Bus Gateway
.
The
Expander Configuration
page displays.
2. From the dropdown list, view the newly assigned PSU ID.
An exclamation mark (!) prefixes the PSU ID you assigned to the device. This indicates that there is
an input transponder available to assign to the PSU.
3. Take a note of the number in brackets next to the PSU ID. This number is the ID you must assign to
the input transponder. For example, if the PSU ID is
ID 14 (27)
, you must manually select a
transponder with
ID 27
from the
Input
dropdown list.
4. From the
Input
dropdown list, select the transponder ID indicated in brackets next to the PSU ID.
5. Click the
Select
button.
6. Go to
Settings > X-BUS > Expanders
.
7. Click
Reconfigure
.
The PSU device displays in the list of
Configured Expanders
.
23.21.1.2 Addressing Transponders for PSU SAP 25
The Sintony PSU SAP 25 has two internal transponders. Each transponder requires an ID. These two IDs
are assigned automatically when you complete the addressing steps described in
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Appendix
© Vanderbilt 2018