
You can connect up to 128 WPAs per SPC panel.
Configure a WPA
To configure a WPA from the browser, select Full Engineer mode and select
Configuration > Hardware
> Wireless > WPA
.
The following items can be checked or configured:
l
Battery Status
The panel receives the battery status from the WPA in every frame. The battery status can be either
OK or Low.
Battery monitoring requires a WPA fitted with the PCB revision E-PC138612 or later.
l
Supervise
The Supervise status can be any of the following:
– Fault
The panel has not received a supervision message from the WPA in the period configured in the
Wireless Settings page.
– Disabled
Supervision is not configured.
– OK
Supervision is transmitting normally.
l
Status
The Test Status can be any of the following:
– Overdue
The WPA has not been tested in the period configured in the Wireless Settings page.
– Disabled
Supervision is not configured.
– OK
The WPA test is ok.
Add a WPA
To add a WPA to the system:
1. Select
Configuration > Hardware > Wireless > WPA
and click the
Add
button . The
Configure
Wireless Personal Alarm (WPA)
page appears.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
213
A6V10276959-d
11.2018