Restriction
System
Option
Description
Web Only
Keypad LED
Policy
Select which LEDs will be displayed on keypads in both Set and Unset modes.
Web Only
System
General Policy
Select options to manage remote control of the system and alarm and bell
settings from the following:
- No confirmed alarms if internally set
- Block remote restore
- Block remote isolates
- Block remote inhibits
- No external bell if internal set
- Delay reporting if entry active
- Confirmed alarm cancels delay
Web Only
Confirmed
Alarms System
Alerts
Select which system alerts cause a confirmed alarms when at least one alarm
is active, and which system alerts cause the panel to enter the tentative state.
Hold-up Data
Web Only
Hold-up
keyword 1
Enter the first hold-up keyword to send to the CMS in a Holdup Information
(HD) event.
Web Only
Hold-up
keyword 2
Enter the second hold-up keyword to send to the CMS in a Holdup Information
(HD) event.
Web Only
Phone number
1
Enter the first site phone number to send to the CMS in a Holdup Information
(HD) event.
Web Only
Phone number
2
Enter the second site phone number to send to the CMS in a Holdup
Information (HD) event.
*
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
See also
17.10.3.2 Timers
This page gives an overview about identified timer defaults and their description.
These settings, which vary depending on the defined Security Grade of the system, should only be
programmed by an authorised installation engineer. Changing settings could render the SPC system
noncompliant with security standards. Setting the Security Grade back to EN 50131 Grade 2 or EN
50131 Grade 3 overwrites any changes made on this page.
1. Select
Configuration > System > System Timers
.
The
System Timers
page displays.
2. Configure the fields as described in the following table.
Timers
Designation of the functions in the following order: