Fault Finding
Fault Isolation Flowcharts
Strata DK I&M 6/00
14-15
Fault
F
inding
Flowchart 14-6
Voice Mail/(External) Auto Attendant Faults
Is the
fault
cleared?
Yes
END
START
This chart assumes
the VM/AA device
has no faults.
Is the
fault
cleared?
Yes
6-3
No
6-2
Is VM/AA
integration completely
non-operational?
END
Yes
Read “Voice Mail Options” in Chapter 10 and
the programming instructions for:
DK14/DK40i: 03 (Code 92, slot 00 for
K4RCU3) DK424: 03 (Code 92~94 for RCTU
PCB) DK14/DK40i/DK424/DK424i: 15-0 and
15-3 (Auto release), and 31 (LEDs: 04, 05, 09,
15~20). This explains system hardware and
programming options related to VM and
external auto attendant.
Correct Hardware/System Programming as
necessary.
Check that the VM I.D. codes (656 and
657) are stored correctly in users’ digital or
electronic telephones. Use operating
procedures in the manual for instructions.
6-1
Check that the QRCU3 (DK14),
K5RCU (DK40i) or RRCS (DK424 or
DK424i) is installed correctly and
programmed with Code 92 in Prog. 03
(DK40i) or Code 92, 93, and 94 in
Prog. 03 (DK424 or DK424i).
No
Check that VM/AA ports are connected to
standard telephone station ports correctly.
(Refer to QSTU2 (DK14), KSTU2 (DK40i
only). DK40i/DK424 RSTU2, PSTU, PESU,
and for the DK424 or DK424i, RDSU/RSTS
wiring diagrams in Chapter 10.)
Correct if necessary.
Is the
fault
cleared?
Yes
6-4
No
END
Is the
fault
cleared?
Yes
6-5
No
END
Call your technical
support group.
Using a standard DTMF
telephone, check all standard
telephone circuits (QSTU2,
KSTU2,RSTU2, PSTU2, PESU).
Replace defective PCB if
necessary.
Other VM/AA related programs:
• 10-2, LED 11 – No DTMF tones
• 13 – Message center
• 33 – Station hunting
• 35 – Busy station transfer/ringing
• 36 – Fixed call forward
• 37 – Ring transfer recall time
6-6
No
1884
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...