DK14 Installation
Site Requirements
1-2
Strata DK I&M 6/00
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 10 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire ground. (See
Power and Grounding Requirements” on Page 1-3
for details).
This is to eliminate interference from branch circuit motor noise or the like, and to prevent
accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do
not
use
an On/Off wall switch on this dedicated AC circuit.
For the DK14, a reserve power source (two customer-supplied 12-volt batteries) may be connected
to the system to serve as a power failure backup.
Clearance and Location
The minimum clearance requirements for the DK14
KSU are shown in
. The HPFB should be
mounted directly above the D14 KSU.
Consider the following conditions when selecting a
location for the KSU(s):
The location
must be
:
♦
Dry and clean
♦
Well ventilated
♦
Well illuminated
♦
Easily accessible
The location
must not be
:
♦
Subject to extreme heat or cold
♦
Subject to corrosive fumes, dust, or other
airborne contaminants
♦
Subject to excessive vibration
♦
Next to television, radio, office automation, or
high frequency equipment
2"
2"
16.4"
Front View
Top View
3"
3' Front Clearance
Wall
2"
DK14 KSU
HPFB
2"
2"
10"
2399
Figure 1-1
DK14 KSU Clearance
Requirements
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...