DK424i Configuration
Worksheet 7 – System Power Factor Check
Strata DK I&M 6/00
6-33
DK424i Configuration
Worksheet 7 – System Power Factor Check
The Strata DK power supply was engineered for maximum cost efficiency to provide power for
the most configurations. Because of this design, some -24VDC power limitations exist when using
old electronic-type telephones and/or telephone option hardware. Also some +5VDC power
limitations exist when using RWIU PCBs.
Each telephone/device and PCB has been assigned Power Factors (PFs) that reflect the amount of
power supply resources they consume. The Power Supply Unit has also been assigned Power
Factors that reflect how much power it can supply. To make sure the cabinet power supply is
operating within its limit, it is necessary to add up the PFs of each telephone/device and PCB
installed in each cabinet to verify that their total PFs do not exceed the Power Supply PF.
Use the work sheets provided on
to calculate that each cabinet PF is within
limits.
Important Power Factor Considerations
♦
The individual PCB and telephone power factors can be found on
and
♦
The sum of all PCB and telephone –24VDC PFs in a given cabinet cannot exceed 85.
♦
The sum of all PCB +5VDC PFs in a given cabinet cannot exceed 40; telephones do not have
+5VDC PFs.
♦
It is only necessary to check the +5VDC PF of a cabinet if RWIU PCB(s) are installed.
♦
If a cabinet PF is exceeded it is necessary to reconfigure the cabinet to meet PF limits.
♦
If a cabinet’s Power Factor is exceeded, cabinet or connected peripherals may malfunction
during ringing or voice paging, whereas normal operation will occur for idle telephones.
♦
The DK424i, PSUB672 power supply provides a PF alarm LED and reset button. If this LED
is on, reset it with the reset button. Then recheck the cabinet PFs to make sure they are within
limits.
Note
PCB Power Factor calculation examples are shown in
.
Table 6-22
Strata DK424i Base Cabinet
PCB
Quantity
+5VDC PF
-24VDC PF
PDKU
2
1.6
0.6
RBSU + RBSS
1
3.1
0.3
RCOU + RCOS
1
3.6
4.0 (8 COs)
B1CU
1
2.0
1.0
BRCS1A-4
1
0.4
0.3
RWIU
1
9.2
0.0
Total
7
19.9
6.2
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...