Universal Slot PCBs
RDTU – T1 Interface Unit
9-52
Strata DK I&M 6/00
Figure 9-26 RSIU Installed into an Existing System without DID and/or Tie Lines
➤
To move the PCB to the next highest slot
1. Identify (mark) the attendant console and all station PCB wiring connectors so they can be
removed and then reinstalled on the same PCB later (console station PCBs include: PDKU,
RDSU, PEKU, PESU, RSTU, PSTU and RATU PCBs).
2. Turn system power Off.
3. Disconnect the connectors from the attendant console and all station PCBs listed in Step 1.
4. Remove all station PCBs listed in Step 1.
5. Install each PCB that was removed in Step 4 into the next highest empty station PCB slot
number. Skip over all other types of PCBs that were not removed. Example: If a PDKU was
originally in slot 11 and a PSTU was in slot 12, the PDKU is moved to slot 12 and the PSTU is
moved to slot 13. The programming telephone will then be on the 6th circuit (port 005; or, 013
until Program 03 Code 49 is set for slot 11) of the PDKU in slot 12.
6. Connect all PCB connectors that were removed back into the same PCBs they were removed
from in Step 3.
7. Turn the system power On and note that the programming telephone is on port 13 and all other
ports are shifted up by eight ports. Program slot 11 with Code 49 and all other slots with the
appropriate codes using Program 91-1 and/or 03.
Next, cycle system power Off (five seconds) and On, or, run Program 91-2 to transfer Program
03 data from temporary to working memory. At this time the programming telephone changes
from port 13 to port 005 and all other ports shift down by eight ports.
R11
S11
RCTU
S12
S13
SLOT
DK424 Base Cabinet with RCTUC3 / D3
or RCTUBA3 / RCTUBB3 / RCTUE3 / RCTUF3
PCB
TYPE
RCTUC3 or
RCTUBA3
or
RCTUE3
RCTUD3
or RCTUBB3
or RCTUF3
RSIU
RSIS
or
RMDS
PDKU
or
PEKU
Port 4
Port 3
Port 2
Port 1
Install ribbon
cables as shown
2-connector Ribbon Cable
(supplied with RCTU)
Ribbon Cable
3-connector Ribbon Cable
(supplied with RSIU)
R11
S11
RCTU
S12
S13
SLOT
DK424 Base Cabinet
with RCTUA3
PCB
TYPE
RCTUA3
RSIU
RSIS
or
RMDS
PDKU
or
PEKU
Port 4
Port 3
Port 2
Port 1
Ribbon Cable
Install ribbon
cables as shown
1815
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...