DK424 Installation
Wall Mounting
5-12
Strata DK I&M 6/00
10. Hang the Base Cabinet or first Remote Expansion Cabinet back cover from the top two screws
and secure the screws into the wall.
11. Drill holes at the bottom two mounting holes of the back cover, and secure #12 X 1.25 inch
wood screws into the two holes.
12. If installing a Base Cabinet or first Remote Expansion Cabinet: Position the cabinet on the
back cover cabinet hangers, slide the cabinet to the right to the proper mounting position, and
secure the cabinet to the back cover with two screws on the right side of the cabinet. If
installing Expansion Cabinets, skip to
“Cabinet Floor Mounting” on Page 5-21
.
13. Install ground wiring, AC and reserve power cabling, and PCB cabling per the
“Recommended Installation Sequence” on Page 5-7
14. Fill out the slot identification label on the cabinet (see
15. Reinstall the front cover, top cover, and side covers onto the cabinet.
Expansion Cabinet Installation (DKSUE424)
Note
Toshiba recommends installing cabinets (see
) from the top
down, with the Base Cabinet on top, the first Expansion Cabinet below it, the second
Cabinet below that, etc.
1. Remove the front, back, and side covers from the Expansion Cabinets.
Note
The bottom left screw must be completely removed. The two screws on each side cover
and the three screws on the front cover should only be loosened and the covers slid to the
right for removal.
2. Hold an Expansion Cabinet back cover against the wall so that its top locating parts align with
the bottom locating parts of the Base Cabinet back cover. To secure the Expansion Cabinet
back cover to the wall or wall board, repeat Steps 5~11 from
First Remote Expansion Cabinet Installation” on Page 5-11
3. To install additional Expansion Cabinet back covers, repeat Step 2 above.
4. Starting with the top Expansion Cabinet back cover (which is fastened to the wall), position an
Expansion Cabinet on the back cover cabinet hangers. Slide the cabinet to the right to the
proper mounting position, and secure the cabinet to the back cover with two screws to the right
side of the back cover. Repeat for all other Expansion Cabinets.
5. Loosen the bonding connection plates fastened on both sides of the first Expansion Cabinet,
then fasten the plates between the Base Cabinet and the first Expansion Cabinet. Repeat to
connect the first Expansion Cabinet to the second Expansion Cabinet, etc.
6. Base Cabinet: Loosen data cable door locking screws and open data cable doors; then connect
the first Expansion Cabinet data cable to the “CAB 2” (top) data cable connector on the Base
Cabinet. Install data cables in appropriate connectors for all other Expansion Cabinets).
...or Remote Expansion Cabinet. See details on
7. After all data cables are installed, close data cable doors and secure with the locking screw.
Important!
Data cable door screws must be firmly tightened for proper system operation.
8. Install ground wiring, AC and reserve power cabling, and PCB cabling per the
“Recommended Installation Sequence” on Page 5-7
9. Fill out cabinet/slot identification labels on each cabinet.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...