ISDN Interfaces
RPTU Installation
16-8
Strata DK I&M 6/00
RPTU Installation
Before installing a RPTU PCB into a DK system, a number of system programs should be run.
This enables the RPTU to function immediately upon insertion. It is recommended that you run
these programs in the order listed in the
DK Programming Manual
(refer to the ISDN section)
before beginning installation.
Refer to Worksheet 6 in the
Strata DK I&M Manual
– Chapter 6.
Also, see
and
➤
To install an RPTU PCB
1. Set the jumper wire plugs JP1 and JP2 (LB) to the Off position.
2. Turn the DK system power Off.
3. Insert the RPTU (component side facing right) into the appropriate slot (see “Slot
Assignments” on
“DK424 Slot Assignments” on Page 16-6
) and apply firm, even pressure to
ensure proper seating of connectors.
4. After installing the RPTU, gently pull the PCB outward. If the connectors are properly seated,
a slight resistance is felt.
Note
For cabling information and requirements, refer to
.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...