Section 32: Functions
T
ieline
Page 309
T E C H N O L O G Y
33.4.4.
Parameter: Renegotiating and Retraining
The
Parameter
menu within the
Task Rule
menu is linked to the
Connection Manager Category
as shown in this example. It
allows you to set the bit-rate at
which you want the codec to
renegotiate to in POTS or IP
modes.
You can also set the POTS
modem to retrain up or down,
depending on current line
quality, or to connect at the
current setting as set in the
POTS menu within the
Profile
Editor
.
In the example above the modem is being programmed to renegotiate up
when the User Function is executed.
Parameter
is also used to set the
Pulse
time in milliseconds for relay use.
33.4.5.
Parameter: Setting Dialing User Functions
Parameter
is also used if you are setting a User Function which uses
Dial
Memory
in the
Operation
menu.
Parameter
will then allow you to select a
phone number entry from the
Phonebook Editor
. In the following example
entry 14 is programmed to be dialed.
Please see the Failover Profile section in this manual for more information in
relation to the previous
Task Rule
example.
33.4.6.
Parameter: Setting One RU LED Blink Times
Parameter
is also used if you are setting a User Function which uses the
indicator LEDs on a
COMMANDER
G
3
one RU codec. The
Parameter
setting in this circumstance is used to enter the blink time in milliseconds of
the LED that is being programmed via a user function.