Section 9: Quick Start
T
ieline
Page 41
T E C H N O L O G Y
9.3.
Step 3: Change Connection Settings
Next, adjust any connection settings. To do this simply scroll with the
MENU SELECTOR (MS)
to the connection you will be using (POTS, ISDN, GSM, 3G, X.21 or IP). Next press
SOFTKEY
3 Wiz
to open the wizard for that connection. Press
SOFTKEY 4 OK
to proceed through the
wizard options for that connection.
Once you have opened the wizard, the current menu configuration settings will have the two
inward pointing arrows (
→
←
) next to them. Press
SOFTKEY 4 OK
to save any new selections
that you have scrolled to with the
MENU SELECTOR,
or to keep any of the current settings and
continue through the wizard. Press
SOFTKEY 3 Exit
to exit the wizard at any time (any changes
prior to exiting the menu will be saved). Press
SOFTKEY 1 Prev
to navigate to the previous
wizard menu item.
Figure 8: POTS Menu Wizard Screen Displaying Editing Functionality Available
The menu structure of the POTS, ISDN, GSM, X.21, 3G/IP and IP connection wizards is displayed
in the next few pages. Following this is a brief discussion about algorithm and connection bitrates,
including suggested rule-of-thumb minimum connection bitrates for different connection types. We
then complete this section of the manual with quick start connection procedures for each manual
default profile and connection type.