Section 33: Functions Tab
T
ieline
Page 302
T E C H N O L O G Y
33.4.3.
Object and Operation Menus
The next two menu selections for
Task Rule
,
Object
and
Operation
, will be
looked at together but in relation to relevant
Category
and
Type
settings. The
Object
menu sets the specific input, relay etc. and the
Operation
menu sets
the actual effect on that
Object
.
Table 19: Functions Menu - Object and Operation Menus
Category
Type
Object
Operation Description
Alarms
Piezo
Alarm
‘Grayed-
out’ and
inactive.
Beep 1-10
times or
forever.
The piezo alarm can be set to
beep between one and ten
times or until cancelled by the
operator.
Audio
Control
Input
Type
Inputs 1-5
Toggle
If set to
Toggle
, the User
Function will toggle the setting
through the list of mic input
level settings.
High Gain
Mic
Sets the mic input level to
High
Gain Mic
.
Med Gain
Mic
Sets the mic input level to
Med
Gain Mic
.
Low Gain
Mic
Sets the mic input level to
Low
Gain Mic
.
Un-
balanced
Sets the mic input level to
Unbalanced Gain Mic
.
Line Level Sets the mic input level to
Line
Level
mic gain.
Input
State
Inputs 1-6
Off
The input will be switched off
when the User Function is
initiated.
On
The input will be switched on
when the User Function is
initiated.
Toggle
The input will toggle between
on and off each time the User
Function is executed.
Key
The input will be on for the
duration a key is pressed i.e. a
SOFTKEY
(The
Activation Rule
Trigger
setting should be
Momentary
.)
Table continued on the next page…