Specification— 2440 Service
Table 1-1 (cont)
Characteristics
Performance Requirements
TIME BASE
Sample Rate Accuracy
Average Over 100 or More Samples
± 0.0015% .a
External Clock
Repetition Rate
Minimum
1 MHz.®
Maximum
100 M H z.a
Events Count
1 to 65,536®
Events Maximum Repetition Rate
100 MHz.®
Signal Levels Required for EXT Clock or EVENTS
Channel 1 or Channel 2 SOURCE
DC Coupled
0.7 division from DC to 50 MHz; increasing to 2.0 divisions at
100 MHz; 3.0 divisions at 100 MHz in ADD mode.®
NOISE REJ Coupled
2.4 divisions or less from DC to 50 MHz; increasing to 6.0 divi
sions at 100 MHz; 9.0 divisions at 100 M Hz in ADD mode.®
AC Coupled
0.7 division from 60 Hz to 50 MHz; increasing to 2.0 divisions at
100 MHz; 3.0 divisions at 100 MHz in ADD mode. Attenuates sig
nals below 60 Hz.®
HF REJ Coupled
1.0 division from DC to 30 kHz. Attenuates signals above
30 kHz.®
LF REJ Coupled
1.0 division from 80 kHz to 50 MHz; increasing to 2.0 divisions at
100 MHz; 3.0 divisions at 100 MHz in ADD mode. Attenuates sig
nals below 80 kHz.®
EXT TRIG 1 or EXT TRIG 2 Source
Ext Gain = 1
DC Coupled
35 mV from DC to 50 MHz; increasing to 100 mV at 100 MHz.®
NOISE REJ Coupled
120 mV or less from DC to 50 MHz; increasing to 300 mV at
100 MHz.®
AC Coupled
35 mV from 60 Hz to 50 MHz; increasing to 100 mV at 100 MHz.
Attenuates signals below 60 Hz.®
HF REJ Coupled
50 mV from DC to 30 kHz.®
LF REJ Coupled
50 mV from 80 kHz to 50 MHz; increasing to 100 mV at
100 MHz.®
Ext Gain = -=- 5
Amplitudes are five times those specified for Ext Gain = 1.®
1-13
‘ Performance Requirement not checked in the manual.
Summary of Contents for 2440
Page 4: ......
Page 12: ......
Page 38: ......
Page 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Page 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Page 130: ...Theory of Operation 2440 Service 3 88 ...
Page 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Page 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Page 208: ......
Page 322: ......
Page 419: ......
Page 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Page 427: ......
Page 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Page 429: ......
Page 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Page 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Page 439: ......
Page 445: ......
Page 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Page 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Page 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Page 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Page 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Page 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Page 490: ...YES ...
Page 492: ......
Page 494: ......
Page 499: ...YES ...
Page 501: ......
Page 502: ...2440 Service FIG 1 C A B IN E T ...
Page 503: ......
Page 510: ...2440 Service SISSVHO Z Old ...
Page 511: ......
Page 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Page 513: ......
Page 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Page 518: ...2440 Service ...
Page 519: ...FIG 4 L V H V PWR SUPPLY ...
Page 520: ...FIG 5 ACCESSORIES 2440 Service ...
Page 521: ......
Page 523: ......
Page 529: ......
Page 530: ......
Page 531: ......