![Tektronix 2440 User Manual Download Page 154](http://html1.mh-extra.com/html/tektronix/2440/2440_user-manual_1078860154.webp)
Performance Check and Functional Verification Procedure
2440 Service
5. Check CH 1 and CH 2 Position Range.
a.
Recall the Initial Front-Panel Setup, labeled “FPNL”
(see step i in “INITIAL S E T U P ” at the start of this
procedure). Make the following changes to the
front-panel setup:
Set:
Set:
CH 1 VOLTS/DIV
20 mV
CH 2 VOLT/DIV
20 mV
A S E C /D IV
10 (is
VERTICAL M O DE
CH 2
Off
b.
Connect a 50 kH z reference frequency signal from the
Leveled Sine-Wave Generator to the CH 1 OR X input
connector via a 50 XI Coaxial Cable and a 5X Attenua
tor.
c.
Adjust the Leveled Sine-Wave Generator’s output level
for a 4-division display on screen.
d.
Remove the 5X Attenuator and connect the 50 0
Coaxial Cable directly to the CH 1 OR X input connec
tor.
e.
Rotate the CH 1 POSITION control full clockwise and
hold until the waveform no longer moves up screen.
f.
C H E C K -T h a t the bottom of the waveform is within
+ 0.4 to -0 .7 division of the center horizontal grati
cule line.
g.
Rotate the CH 1 POSITION control full counter-clock
wise and hold until the waveform no longer moves
down screen.
h.
C H E C K —T h a tth e to p o f the waveform is within + 0 .7 to
-0 .4 division of the center horizontal graticule line.
i.
Reinstall the 5X Attenuator and move the 50 H Coaxial
Cable to the CH 2 OR Y input connector.
j.
Select VERTICAL M O DE and set CH 2 on and CH 1 off.
k.
Repeat parts c through h to check CH 2 ’s position
range, using the CH 2 OR Y input connector and
controls.
6. Check CH 1 and CH 2 Bandwidth and
Bandwidth Limit (20 MHz and 100 MHz).
a.
Recall the Initial Front-Panel Setup, labeled “FPNL”
(see step i in “INITIAL S E T U P ” at the start of this
procedure). Make the following changes to the
front-panel setup:
CH 1 VOLTS/DIV
2 mV
CH 2 VOLTS/DIV
2 mV
A SEC /D IV
100 ns
VERTICAL M ODE
CH 2
Off
b.
Connect the output of the Secondary Leveled
Sine-Wave Generator to the CH 1 OR X input connector
via a 50 O Precision Coaxial Cable, a 10X Attenuator,
and a 2X Attenuator.
c.
Set the Leveled Sine-Wave Generator output level for a
6-division display at the 6 M H z reference frequency,
then change the output frequency to 300 MHz.
d.
Set A SE C /D IV to 2 ns.
e.
C H E C K —The display am plitude is 4.2 divisions
or greater.
f.
Return the A S E C /D IV to 100 ns and set the CH 1
VOLT/DIV control to the next higher setting.
g.
R ep eatp artscth ro u g h ffo rall CH 1 VOLTS/DIV settings
through 500 mV, removing and/or adding 10X, 5X, and
2X Attenuators as necessary to allow adjusting the
Leveled Sine-Wave Generator output level to 6 divi
sions.
h.
Return A SE C /D IV to 100 ns.
i.
Select VERTICAL M O D E and set CH 2 on and CH 1 off.
j.
Repeat parts b through g to check CH 2 bandwidth,
substituting CH 2 controls and input connector.
k.
Set A S E C /D IV to 10 fis.
l
.
Disconnectthe Secondary Leveled Sine-W ave Genera
tor from the CH 1 OR X input connector.
m. Connect the output of the Primary Leveled S ine-w ave
generator to the CH 2 OR Y input connector via a
precision 50 H Coaxial Cable and any combination of
the 10X, 5X, and 2X attenuators that reduces the signal
amplitude to the level called for in part n
n.
Set the Primary Leveled Sine-Wave Generator to a
50-kH z reference frequency and adjust the output level
for a 6-division display (change 10X, 5X, and 2X
Attenuators as required).
o.
Select VERTICAL BANDW IDTH and set 20 M Hz on. Set
the A S E C /D IV to 20 ns.
4-12
Summary of Contents for 2440
Page 4: ......
Page 12: ......
Page 38: ......
Page 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Page 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Page 130: ...Theory of Operation 2440 Service 3 88 ...
Page 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Page 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Page 208: ......
Page 322: ......
Page 419: ......
Page 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Page 427: ......
Page 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Page 429: ......
Page 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Page 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Page 439: ......
Page 445: ......
Page 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Page 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Page 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Page 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Page 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Page 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Page 490: ...YES ...
Page 492: ......
Page 494: ......
Page 499: ...YES ...
Page 501: ......
Page 502: ...2440 Service FIG 1 C A B IN E T ...
Page 503: ......
Page 510: ...2440 Service SISSVHO Z Old ...
Page 511: ......
Page 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Page 513: ......
Page 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Page 518: ...2440 Service ...
Page 519: ...FIG 4 L V H V PWR SUPPLY ...
Page 520: ...FIG 5 ACCESSORIES 2440 Service ...
Page 521: ......
Page 523: ......
Page 529: ......
Page 530: ......
Page 531: ......