Adjustment Procedure— 2440 Service
e. Move the test setup to the CH 2 input connector.
f. Select VERTICAL M O DE and set CH 2 on and
CH 1 off.
g. Set CH 2 VO LTS/DIV to 10 mv.
h. Repeat parts c and d, adjusting R233 for part d.
i. Disconnect the test setup.
6. 20 and 100 MHz Bandwidth Limit Filter
Adjustment (TV-Option 05 Only)
a. If
a
menu
is
displayed,
press
the
MENU
OFF/EXTENDED FUNCTIONS button to remove it from
the screen. Select SETUP PRGM and press the menu but
ton labeled INIT PANEL. Make the following changes to
the front panel setup:
Set:
A SEC/DIV
50 ns
CH 1 VOLTS/DIV
10 mV
Select BANDWIDTH
Set:
20 M Hz
On
Select CH 1 COUPLING/INVERT
Set:
50 Q ONIOFF
ON
Select STORAGE ACQUIRE
Set:
REPET ONIOFF
ON
AVG
On (8)
b. Connect the positive-going, FAST RISE output of
the Calibration Generator to the CH 1 input via a precision
50 0 cable and a 10X attenuator.
c. Set the generator output level for a 5 division
display at a frequency of 100 kHz.
NOTE
Adjust the coils in the following parts so their slugs
are out approximately the same amount.
d. ADJUST— L531 for as flat a response as possible.
This coil is located on the Main circuit board.
e. Move the test setup to the CH 2 input connector.
f. Select VERTICAL MODE and set CH 2 on and
CH 1 off.
g. Set the CH 2 V O LTS/DIV control to 10 mV.
h. Repeat parts c and d for CH 2, adjusting L431 for
part d.
i. Set the A SEC/DIV control to 100
ns.
j. Connect the Leveled Sine-wave Generator output via
a 50 fl precision cable and two 10X attenuators to the
CH 2 input connector.
k. Set the generator to produce a 50 kHz, 5 division
display.
l
. Increase the generator output to 5 M H z and set the
SEC/DIV control to 500 ns.
m. Check that the display amplitude is between 4.80
and 5.05 divisions.
n. Select BANDWIDTH and set 100 M H z on. Set the A
SEC/DIV control back to 50 ns.
o. Select VERTICAL M O DE and set CH 1 on and
CH 2 off.
p. Repeat parts b through h to adjust the 100 MHz
bandwidth limit, adjusting R431 and R233 in part d (adjust
R431 when adjusting for CH 1, R233 for CH 2). These
resistors are located on the Main board.
q. Disconnect the test setup.
7. Video Input Gain Adjustment
(TV-Option 05 Only)
NOTE
In part a, you will connect the ground lead of a X10
probe to pin 5 of J125 on the processor board. Be
sure you are connecting to the correct pin. Pin 1 is
marked with a square pad, and all odd-numbered
pins are in the same row as pin 1. Pin 5 is the
second pin up from pin 1.
5-2 0
REV SEP 1988
Summary of Contents for 2440
Page 4: ......
Page 12: ......
Page 38: ......
Page 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Page 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Page 130: ...Theory of Operation 2440 Service 3 88 ...
Page 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Page 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Page 208: ......
Page 322: ......
Page 419: ......
Page 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Page 427: ......
Page 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Page 429: ......
Page 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Page 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Page 439: ......
Page 445: ......
Page 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Page 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Page 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Page 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Page 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Page 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Page 490: ...YES ...
Page 492: ......
Page 494: ......
Page 499: ...YES ...
Page 501: ......
Page 502: ...2440 Service FIG 1 C A B IN E T ...
Page 503: ......
Page 510: ...2440 Service SISSVHO Z Old ...
Page 511: ......
Page 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Page 513: ......
Page 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Page 518: ...2440 Service ...
Page 519: ...FIG 4 L V H V PWR SUPPLY ...
Page 520: ...FIG 5 ACCESSORIES 2440 Service ...
Page 521: ......
Page 523: ......
Page 529: ......
Page 530: ......
Page 531: ......