![Tektronix 2440 User Manual Download Page 229](http://html1.mh-extra.com/html/tektronix/2440/2440_user-manual_1078860229.webp)
M aintenance— 2440 S ervice
Reverse parts a through I to install the Side board in
the instrument. Take care to fit the rear edge of the board
to the channel notch when reinstalling to the chassis.
7. High V o lta g e P o w er S upply B oard R em oval
a.
Perform Step 1 to remove the cabinet from the
instrument.
b.
Set the instrument on a flat, smooth surface with
the High Voltage Supply board facing up and the Front
panel facing forward.
W A R N I N G
T h e C R T a n o d e le a d m a y re ta in a h ig h -v o lta g e
c h a rg e a fte r th e in s tru m e n t is p o w e re d o ff. T o a v o id
e le c tric a l sh o c k , g ro u n d th e C R T a n o d e le a d to th e
m e ta l c h a s s is a fte r d is c o n n e c tin g th e p lu g . R e c o n
n e c t a n d d is c o n n e c t th e a n o d e -le a d p lu g s e v e ra l
tim es, g ro u n d in g th e a n o d e le a d to c h a s s is g ro u n d
e a c h tim e it is d is c o n n e c te d to fu lly d is s ip a te th e
c h a rg e .
c.
Remove the anode lead from the retaining hook that
secures it to the Main chassis.
d.
Disconnect the CRT lead (male end) from the High
Voltage Module lead.
e.
Remove the single screw securing the High Voltage
Power Supply and lift the High Voltage shield off.
W A N N I N G
I
T h e fiv e m o u n tin g p o s ts o n th e s id e o f th e H ig h V olt
a g e m o d u le (U 5 6 5 ) m a y re ta in a h ig h -v o lta g e c h a rg e
a fte r th e in s tru m e n t is p o w e re d o ff. To a v o id e le c
tric a l sh o c k , d is c h a rg e th e s e p o s ts to th e m e ta l
c h a s s is th ro u g h a n a p p ro p ria te s h o rtin g s tra p .
f.
Discharge the five posts on the side of the High Volt
age module to the metal chassis.
g.
Disconnect the cable connectors from J172 and
J173, located at the front edge of the board, and from
J162 and J176, located the rear edge of the board.
h.
Disconnect the remaining ribbon connector from
J105 on the Main board.
i.
Pry outward on either one of two retaining latches
securing the fan on its mounting posts. As the latch clears
the edge of the fan, pull the fan outward and away from
the instrument to remove. The latches are located at
opposite corners; one at the bottom comer nearest the
rear, the other at the top comer nearest the front, of the
instrument.
j.
Perform parts j through I of Step 4 to access the
inside of the instrument.
k.
Disconnect the crt connector from the back of the
crt.
I.
Rotate the two black retaining latches (near the
front- and rear-left corners of the High Voltage Power Sup
ply board) 1/4 turn counterclockwise to unlock them.
m.
While holding its nut (located between the crt shield
and the adjacent Main chassis) stationary, remove the
mounting post (near the center of the board) securing the
High Voltage Power Supply board to the Main chassis.
n.
Lift the left edge of the board up to clear the retain
ing latches. Pull, the board to the left, until its right edge
clears the two channel notches, to complete the removal.
Reverse parts a through n to install the High Voltage
Power Supply board. Take care to fit the left edge of the
board to the channel notches when reinstalling the board.
8. Low V o ltag e Pow er Supply A ssem bly R em oval
a.
Perform Step 1 to remove the cabinet from the
instrument.
b.
Disconnect the ribbon cable connector at J113 of
the Main board to access the mounting screw at the
center of the Side board. Remove that screw.
c.
Remove the mounting screw at the center of the
Side board. Note that for instruments with Option 05
installed, it is necessary to disconnect the ribbon cable
connector at J113 of the Main board to access the mount
ing screw.
6-21
Summary of Contents for 2440
Page 4: ......
Page 12: ......
Page 38: ......
Page 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Page 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Page 130: ...Theory of Operation 2440 Service 3 88 ...
Page 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Page 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Page 208: ......
Page 322: ......
Page 419: ......
Page 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Page 427: ......
Page 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Page 429: ......
Page 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Page 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Page 439: ......
Page 445: ......
Page 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Page 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Page 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Page 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Page 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Page 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Page 490: ...YES ...
Page 492: ......
Page 494: ......
Page 499: ...YES ...
Page 501: ......
Page 502: ...2440 Service FIG 1 C A B IN E T ...
Page 503: ......
Page 510: ...2440 Service SISSVHO Z Old ...
Page 511: ......
Page 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Page 513: ......
Page 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Page 518: ...2440 Service ...
Page 519: ...FIG 4 L V H V PWR SUPPLY ...
Page 520: ...FIG 5 ACCESSORIES 2440 Service ...
Page 521: ......
Page 523: ......
Page 529: ......
Page 530: ......
Page 531: ......