Functions specific to SCALANCE
4.2 Signal recorder
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
98
Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (100 - 60000)> display
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
ms
The interval in milliseconds (ms) be-
tween acquisition of two measured
values
100 - 60000
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The recording is configured and will be started. The measured values are output in the CLI
and logged in files. If these files already exist, they will be overwritten.
Use the
wlan signal-recorder <wlan 0/X> stop
command to stop the recording.
During the recording, it is possible that working in the CLI becomes slower.
Further notes
You stop the recording early with the
wlan signal-recorder <wlan 0/X> stop
command.
You display the status of the signal recorder and the recording with the
show wlan signal-
recorder <wlan 0/X>
command.
4.2.5
wlan signal-recorder display sample_number (Client)
Description
With this command, you configure and start recording with the signal recorder. The
measured values are output in the CLI and logged in files. On completion of the recording,
the files can be downloaded as a zip file using http or tftp. The values are stored every 10
minutes. The file contains all values since the start of the recording.
Note
This command is only available in the client mode.