Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
450
Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters
Description
Range of values / note
up
The message when establishing a connection is
disabled
-
down
The message when a connection is down is disa-
bled
-
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the
show events faults config
command.
You enable the function with the
link
command.
11.1.6.8
send test mail
Description
With this command, you send an e-mail according to the currently configured SMTP settings.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
send test mail
Result
An e-mail according to the currently configured SMTP settings is sent.
Further notes
You can display the current SMTP settings with the
show events smtp-server
command.