Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
441
Syntax
Call up the command with the following parameter:
fault report ack <fault-state-id>
The parameter has the following meaning:
Parameters
Description
Range of values/note
fault-state-id
ID of the mes-
sage
Enter the ID of the message for the "Cold/Warm Start"
event.
To obtain the ID, use the "
show events faults status
"
command.
Result
The message is acknowledged.
11.1.5
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal
command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end
or
exit
command and are then in the
Privileged EXEC mode again.
11.1.5.1
events
Description
With this command, you change to the EVENTS configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
events