![Rohde & Schwarz SMBV100B User Manual Download Page 919](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881919.webp)
Remote Control Commands
R&S
®
SMBV100B
917
User Manual 1178.4460.02 ─ 03
Example:
STAT:QUES:NTR 0
a transition from 1 to 0 in the condition part of the STA-
Tus:QUEStionable register does not cause an entry to be made
in the EVENt part
:STATus:QUEStionable:PTRansition
<PTransition>
Sets the bits of the NTRansition part of the STATus:QUEStionable register. If a bit is
set, a transition from 1 to 0 in the condition part causes an entry to be made in the
EVENt part of the register.
Parameters:
<PTransition>
string
Example:
STAT:QUES:PTR 32767
all transitions from 0 to 1 in the condition part of the STA-
Tus:QUEStionable register cause an entry to be made in the
EVENt part
:STATus:QUEue[:NEXT]?
Queries the oldest entry in the error queue and then deletes it. Positive error numbers
denote device-specific errors, and negative error numbers denote error messages
defined by SCPI. If the error queue is empty, 0 ("No error") is returned.
Return values:
<Next>
string
Example:
:STATus:QUEue?
queries the oldest entry in the error queue.
Response: 0, 'no error'
no errors have occurred since the error queue was last read out
Usage:
Query only
12.19
TEST Subsystem
The
TEST
subsystem contains the commands for performing test routines directly at
the hardware assemblies.
The selftetst responses with a
0
if the test is performed successfully, otherwise a value
other than
0
is returned. None of the commands of this system has a
*RST
value.
..........................................................................................918
.................................................................................................918
............................................................................................919
.................................................................................................919
TEST Subsystem