Configuring the Internal Baseband Source
R&S
®
SMBV100B
249
User Manual 1178.4460.02 ─ 03
5. Adjust further settings, e.g. trigger setting, as required.
Enable signal generation with "Multi-Carrier Continuous Wave > State > ON".
6. Enable the signal output with "RF > ON".
7. On the connected signal analyzer, perform the required measurement tasks. Mea-
sure the frequency response at the outputs of the DUT.
3.9.5
References
Table 3-21: MCCW default values
Parameter
Value
State
Not affected by "Set to Default"
Carrier Setup
Number of Carriers
64
Carrier Spacing
10 kHz
Optimize Crest Factor
Chirp
Desired Crest Factor
3 dB
Trigger
Mode
Auto
Source
Internal
Ext. Delay
0
Ext. Inhibit
0
Marker
Channel 1...4
Restart
Clock
Generating Multi-Carrier Continuous Wave Signal