![Rohde & Schwarz SMBV100B User Manual Download Page 770](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881770.webp)
Remote Control Commands
R&S
®
SMBV100B
768
User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FREQuency
<Frequency>
Sets or indicates the carrier frequency, depending on the selected carrier frequency
mode.
Parameters:
<Frequency>
integer
Range:
depends on the installed options
*RST:
0
E.g. -60 MHz to +60 MHz (base unit)
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier:MODE ARB
SOURce1:BB:ARBitrary:MCARrier:CARRier1:
FREQuency 5.0
Sets 5.0 MHz carrier frequency.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:PHASe
<Phase>
Sets the start phase of the selected carrier.
Parameters:
<Phase>
float
Range:
0 to 359.99
Increment: 0.01
*RST:
0
Default unit: DEG
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier19:PHASe
90
Sets a start phase.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:POWer
<Power>
Sets the gain of the selected carrier.
Parameters:
<Power>
float
Range:
-80 to 0
Increment: 0.01
*RST:
0
Default unit: dB
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier15:POWer
-50
Sets the power of carrier 15 to -50 dB.
Manual operation:
See
SOURce Subsystem