Remote command:
:SYSTem:COMMunicate:NETWork:STATus?
Restart Network
Terminates the network connection of the instrument and subsequently sets it up
again. You can use this function to fix network problems.
Note:
This function restarts only the connection of the instrument to the network. It
does not impact the network itself.
Remote command:
:SYSTem:COMMunicate:NETWork:RESTart
Hostname
Displays the hostname.
Each instrument is delivered with an assigned hostname, a logical name which can be
used instead of the IP address. With the default network settings, the IP address is
allocated by the DHCP server. This address can change each time the instrument is
reconnected. Unlike the IP address, the hostname name does not change.
Note:
This function is password-protected. Unlock the protection level 1 to access it.
●
We recommend that you do not change the default network settings or the host-
name to avoid problems with the network connection.
If you change the hostname, be sure to use a unique name.
Remote command:
:SYSTem:COMMunicate:NETWork[:COMMon]:HOSTname
Workgroup
Sets the individual windows workgroup name of the R&S
SMBV100B. This parameter
is required in case the instrument is integrated in a windows network.
This function is password-protected. Unlock the protection level 1 to access it.
Remote command:
:SYSTem:COMMunicate:NETWork[:COMMon]:WORKgroup
Address Mode
Selects the mode for assigning the IP address.
NOTICE!
Risk of network failure.
Consult your network administrator before performing the following tasks:
●
Connecting the instrument to the network
●
Configuring the network
●
Changing IP addresses
Errors can affect the entire network.
"Auto (DCHP)"
Assigns the IP address automatically, provided the network supports
DHCP (Dynamic Host Configuration Protocol).
"Static"
Enables you to assign the IP address manually.
Remote command:
:SYSTem:COMMunicate:NETWork:IPADdress:MODE