![Rohde & Schwarz SMBV100B User Manual Download Page 202](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881202.webp)
Configuring the Internal Baseband Source
R&S
®
SMBV100B
200
User Manual 1178.4460.02 ─ 03
3. Select "Multi Segment" >
"Sequencing List"
to access the settings for configuring
a sequencing "Play List" for fast automatic processing of the multi-segment wave-
form.
For a description of the provided settings, refer to
Chapter 3.7.3.4, "Multi-Segment
4. Select "Baseband > ARB > General".
The "Load Waveform" confirms that the current multi-segment file is loaded (file-
name as defined with "Output File").
Note:
The provided settings depend on the current waveform.
The "Sequencing List" function for instance requires that:
● Multi segment file is created, i.e. you have executed
"Create Output File/
Create and Load Output File"
.
● "Sequence Table" contains
more than one segment
.
5. Select "Baseband > ARB > Trigger In (MSW)".
For a description of the provided settings, refer to
Chapter 3.7.3.5, "Next Segment
6. Select "Baseband > ARB > General > State > On" to process the configured multi-
segment waveform.
The remote commands required to define these settings are described in
ter 12.16.4.3, "SOURce:BB:ARBitrary Subsystem"
Setting for Handling the Multi-Segment Files and Output File Settings
Level / Clock / Marker Settings
............................................................................. 205
Multi-Segment Waveform Sequencing
..................................................................207
Next Segment Trigger In Settings
......................................................................... 212
3.7.3.1
Setting for Handling the Multi-Segment Files and Output File Settings
Access:
1. Select "Baseband > ARB > General > Create Multi Segment".
The "General" tab comprises standard functions for file handling, like selecting and
loading of files, or determining the output filename.
2. Perform one of the following:
● Select "New List" to create a multi-segment waveform file
● Select "Load List" to load an existing one
3. Add a comment and select "Output File" to define the filename the multi-segment
waveform is created at.
Note:
The provided settings depend on the current waveform.
The "Sequencing List" function for instance requires that:
● Multi segment file is created, i.e. you have executed
"Create Output File/
Create and Load Output File"
.
Generating Multi-Segment Waveform Files