Remote Control Commands
R&S
®
SMBV100B
719
User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:DM:FILTer:PARameter:RCOSine
<RCosine>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:SPHase
<SPhase>
Sets the filter parameter.
Filter Type
Parameter
Parameter
Name
Min
Max
Increment Default
APCO25
Roll-off factor
<Apco25>
0.05
0.99
0.01
0.2
APCO25Lsm
Cut off frequency for the
lowpass/gauss filter
(
:LOWPass/:GAUSs
)
<Cosine>
400
25E6
1E-3
270833.333
COSine
Bandwidth
<FiltParm>
400
depends on the installed
options
*)
1E-3
270833.333
COSine
Roll-off factor
<Cosine>
0.05
1
0.01
0.35
GAUSs
Roll-off factor
<Gauss>
0.15
100000
0.01
0.3
LPASs
Cut-off frequency
<LPass>
0.05
2
0.01
0.5
LPASSEVM
Cut-off frequency
<LPassEvm>
0.05
2
0.01
0.5
PGAuss
Roll-off factor
<PGauss>
0.15
2.5
0.01
0.3
RCOSine
Roll-off factor
<RCosine>
0.05
1
0.001
0.35
SPHase
B x T
<SPhase>
0.15
2.5
0.01
2
*)
100E6 (base unit) / 200E6 (R&S
SMBVB-K523) / 300E6 (R&S
SMBVB-K524)
Parameters:
<SPhase>
float
Range:
0.15 to 2.5
Increment: 0.01
*RST:
2
Example:
SOURce:BB:DM:FILTe:TYPE SPHase
SOURce:BB:DM:FILTer:PARameter:SPHase 0.5
Manual operation:
See
[:SOURce<hw>]:DM:FILTer:PARameter
<Parameter>
Sets the filter parameter of the currently selected filter type.
To set the filter type, use command
[:SOURce<hw>]:BB:DM:FILTer:TYPE
Parameters:
<Parameter>
float
Range:
0.05 to 2.5
Increment: 0.01
*RST:
0.35
SOURce Subsystem